What size breaker do I need for a 220v pool pump?
20 amp breaker
Booster pumps for pool cleaners or solar systems can be operated with 110V or 220V, and are usually connected to a separate timeclock, powered with a dedicated 15 or 20 amp breaker. The wiring of the motor is identical to the wiring for the main pool pump.
Do pool pumps need to be grounded?
Insulated ground wire is required for grounding pumps. Making a mistake grounding and bonding a swimming pool pump can be deadly. Grounding enables faster circuit breaker action, and bonding ties conductive metal parts together so they have the same electrical potential. Together, both reduce the risk of fatal shock.
Can you wire a 3-phase motor wrong?
If a 3-phase motor rotates in the wrong direction, you can swap any two leads to change to the desired direction. One way to test motor direction is to take your best guess on how to connect the leads, then run the motor and note the direction it spins. If you’re wrong, you undo two leads and swap the wires.
What gauge wire should I use for a pool pump?
Connect an 8-gauge wire to the metal posts of the pool, the pump, and the metal plate on the skimmer and then wire that to the pump to bond the entire pool.
Do I need a GFCI breaker for pool pump?
GFCI Breakers And Swimming Pool Equipment – What We Know And Our Recommendations. The National Electric Code requires that all swimming pool pumps be connected to a GFCI breaker.
Does pool pump need to be bonded?
The NEC requires that all electrical equipment, except double-insulated equipment, be bonded together. In addition, all metal within 5 feet of the inside of the pool wall must be bonded with the equipment to form the equipotential bonding grid.
Is L1 hot or neutral?
US AC power circuit wiring color codes
Function | label | Color, common |
---|---|---|
Neutral | N | white |
Line, single phase | L | black or red (2nd hot) |
Line, 3-phase | L1 | black |
Line, 3-phase | L2 | red |
Does a 3 phase motor need a ground?
There is a neutral in a three phase four wire system. All of them need a ground.
Does a 3 phase motor need a neutral?
The balance current in all three phases of the motor leads to no current in the neutral. Therefore, there is no need for neutral in the 3 phase induction motor.
What is the correct replacement motor for model c48m2n111?
The correct replacement motor for model #C48M2N111 is the UST1202. Here is a link on How To Replace the Motor on Your Pool Pump.? Asked on 7/16/2016 by Ted
What is the replacement for model k48m2n116a3?
Hi, The STS1202R Motor is the direct replacement for model # K48M2N116A3 which is a dual speed motor. If you would like to switch from a dual speed motor to a single speed motor you can use the ST1202 motor.
Does the motor model k48m2n111 match the ust1202?
Hello Catalina, for the motor model k48m2n111 it matches the UST1202 motor. I would highly recommend replacing the pump seal, we would need the pump model to get that pump seal kit for you.? Asked on 10/31/2016 by noel
What are the specs of the k48m2n110c2 motor?
Motor spec’s are as follows: Century UST1202, model# K48M2N110C2, Volts: 115/208-230 HP:2 Ph: 1 Code:H RPM: 3450 FR: 56J AMPS: 19.6/10.4-9.8 Total HP = 2.20. Do you carry this motor or equivalent? Also, please provide the proper seal kit?