How do you model a tank in staad pro?
On the Model ribbon tab, select the Structure Wizard tool in the Create group. The STAAD.Pro Physical Modeller Structure Wizard window opens. In the Templates panel, select the Tanks > Modular Tank option.
How do you make a model water tank in staad?
Water Tank Analysis Using STAAD PRO
- 3D Circular Tool in Staad Pro. Select all the members and then choose the Circular Repeat tool from the Geometry menu; the 3D Circular dialog box is displayed. Enter the values as obtained.
- Model creation and 3D rendered views of the water tank.
- STAAD Pro page statement.
Is code for Intze tank design?
Intze type tank is commonly used overhead water tank in India. These tanks are designed as per IS: 3370 i.e. Code of practice for concrete structures for storage of liquids.
What is Intze type water tank?
Intze Tank. Intze Tank. It is used to store large volumes of water at an elevation. Intze Tank essentially consists of a Top Dome (roof), the cylindrical wall and the floor slab, which is a combination of conical dome & bottom spherical dome.
What is base pressure in staad pro?
While, the maximum value of the base pressure obtained from STAAD Pro program was 77 KN/ m2, for the worst value of the calculated bearing capacity 24 KN/m2 (figures 16 and 17).
How do you design a water tank?
Reinforced concrete water tanks are constructed for storing water. The design of reinforced concrete water tank is based on IS 3370: 2009 (Parts I – IV)….1. Types of RCC water tank.
Types of water tanks | |
---|---|
Based on water tank location | Based on water tank shape |
Tank resting on grounds | Circular tank |
How do I calculate my overhead water tank capacity?
Water Tank Size Calculation Formula:
- Area of Tank = Capicity of Water Requirement / Assume depth.
- L x B = Area of Tank.
- Take Length as 2 Times of B, so L= 2B.
- 2B x B = Area of Tank.
- 2B2 = ank) / 2]
- There for L = 2BArea of Tank.
- B2 = (Area of Tank) / 2.
- B = Sqrt [(Area of T.
What are the different structural elements of an Intze tank?
it is a gravity dam with an almost triangular cross-section. the wall is made of rubble stone with a high proportion of mortar. it has a curved ground plan. it has facing brickwork (Vorsatzmauerwerk or Verblendung) on the upper part of the upstream side.
What is notional load in STAAD?
A notional load is a lateral load (horizontal load) which is derived from an existing vertical load case. This load type has been introduced to accommodate a requirement in design codes.
How do I check plate stress in staad pro?
The bending stress would then be M/S. Alternately STAAD.Pro does report the combined stress for plates. This is available within the Combined Stress tab inside the Plate Center stress table. For the selected plate, note the Top combined stress ( Comb Sx or Comb Sy as appropriate ).
How do you find base pressure in staad?
In STAAD.Pro, go to the Post Processing Mode, Node > Base Pressure table and you will be able to see the base pressure values at the various nodal points in the mat.
Is code for tank design?
The codes that are used for water tank design is IS: 3370. The different parts of the code is mentioned along with the respective sections dealt.
What is the rise of top dome in Intze tank?
Components of Intze tank: Top dome: In general, we provide 100 mm to 150 mm thick dome at top with reinforcement along the latitudes and longitudes. Usually, the rise of the dome is l/5th of the length.
How do you calculate water tank design?